- Tool controls the tip of the ET tube and bends it down to conform with the direction of the trachea
|
- Comfortable closed cell foam padded backing for patient comfort
- Quick connect ratchet system securely holds ET tube in place
- Eliminates the need for messy tape
- Fits perfectly with ET tube sizes 3.0mm - 9.0mm
|
- Ideal for teaching intubation techniques with laryngoscopes, airways, endotracheal tubes and masks.
- Model provides accurate simulation of mouth, nostrils, teeth, tongue, pharynx, epiglottis, vocal cords, trachea, esophagus and lungs.
- Left side of the head is cut away and the walls of the pharynx and trachea are open for easy viewing of proper intubation placement
- Alarms sound when excess pressure is sensed on the teeth
- Comes with carry case, access tray and lubricant.
|
- Rapidly and reliably confirms if endotracheal tube placement is correct or not
- Very simple tool that uses the anatomical difference between the esophagus and trachea as its working principle
- Instant feedback - no need for initial ventilation through the tube to obtain CO2 detection and since no initial ventilation is needed, potential stomach inflation is eliminated
- Bulb version can illuminate in the dark, making it the ideal choice for EMS
|
- Tum-E-Vac
- Assists with naso-gastric tube placement
- Accommodates up to a 40Fr tube
- Non-sterile
- Individually wrapped
|
- Rigid, yet compressible design prevents damage to LMAs, dental work and fingertips
- Convenient handle provides quick simple insertion
|
- Designed for fast, easy airway assessment
- Verifies proper endotracheal tube placement
- Expansive 2" diameter Visual Indicator makes rapid breath-to-breath response easy to see
- Anti-fogging agent reduces susceptibility to moisture and humidity, while ensuring lens clarity
|
- 100' flexible, lightweight tubing with perforations every 6"
- Tapered cuffes securely attach to most 22mm respiratory therapy applications
- Also available in convenient 6" pre-cut lengths
|
- Deflates and inflates high volume, low pressure endotracheal or tracheal cuffs.
- Helps to eliminate the need for syringes, electricity, or complicated connections required to check cuff pressure
- Gauge shows recommended pressure range in cm H2O
- May be left in place for constant monitoring.
|
- A simple, rapid technique for changing endotracheal tubes
- Can be done in less than two minutes
- Available for all sizes of ET Tubes
- Polyethylene
|
- A simple, rapid technique for changing endotracheal tubes
- Can be done in less than two minutes
- Available for all sizes of ET Tubes
- Polyethylene
|
- Permits positioning of tracheal tube Y piece & tracheal tube connections at any convenient angle.
- Flexible metal adapter with 15mm male/female fittings
- Chrome plated
|
- Specifically deisgned for use only with LarySeal Mask Airways
- Color-coded plunger indicates the maximum amount of air appropriate for each mask airway size
|
- Small whistle diaphragm attached to the tube connector magnifies breath sounds
|
- For inflation and pressure control on tracheal tubes with high volume, low pressure cuffs
- Pressure range from 0-60cm H20 recommended green range from 5-15cm H20 and release valve for sensitive adjustment of the desired cuff pressure
- Complete with 100cm connecting tubing
|
- For inflation and pressure control on tracheal tubes with high volume, low pressure cuffs
- Complete with 100cm connecting tubing
|
- Monitors endotracheal cuff pressure level between 20-30cm H20
- Guards against aspiration and tracheal damage
- Pressure feedback line designed to eliminate cuff leaks at peak respiratory pressure
|
- Adult, clear, fits 7mm-10.5 O.D. tubes
- Allows movement of the breathing circuit at the patient end and eliminates the need for connectors of various types and sizes
- Provides firm & tight seal
- Reusable, autoclavable
|
|
|
|
|
- Fills, monitors and adjusts cuff pressure of low pressure endotracheal, endobronchial and tracheostomy tubes
- Helps minimize damage to the mucous membranes of the tracheal wall when used to monitor cuff pressure
- Easy-to-read gauge features a green zone that highlights the recommended inflation pressure range
- One-handed operation
- Fingertip trigger switch increases and maintains desired cuff pressure
- Designed to hang from nearby anesthesia equipment
|
- Standard 15mm male straight slip joint
- Constructed of durable plastic
- Lightweight
- Sized for instant identification and exact fit
- Autoclavable
- Sized according to ID
|
- Latex free thermoplastic rubber construction prevents broken teeth
- Avoids trauma to tissue
|